Fluke® FLUKE-376 True RMS AC/DC Clamp Meter, 999.9 A 1000 V AC/DC, 60 kOhm, 500 Hz, 34 mm Jaw, Backlit Display
Fluke® FLUKE-376 True RMS AC/DC Clamp Meter, 999.9 A 1000 V AC/DC, 60 kOhm, 500 Hz, 34 mm Jaw, Backlit Display
Fluke® FLUKE-376 True RMS AC/DC Clamp Meter, 999.9 A 1000 V AC/DC, 60 kOhm, 500 Hz, 34 mm Jaw, Backlit Display
- Brand: Fluke®
- Mfr# : FLUKE-376
- Item # : FLU 376
- UPC #: 095969558570
- Min. Order Qty: :
- Qty. Interval: :
FEATURES
- IFlex™ flexible current probe expands the measurement range to 2500 A ac
- CAT IV 600 V/CAT III 1000 V
- True-rms ac voltage and current for accurate measurements on non-linear signals
- Min/max/average and inrush recording to capture variations automatically
- Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environments while providing stable readings
- Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
- Ergonomic design fits in your hand and can be used while wearing protective equipment
- Large/easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
- Soft carrying case
- Accuracy - 2% +/- 5 digits dc current/1.5% +/- 5 digits (20 - 500 Hz) ac voltage/1% +/- 5 digits dc voltage/ 1% +/- 4 digits capacitance/1% +/- 5 digits mV dc
- Resolution - 0.1 A ac current via jaw/0.1 A (= 600 a)/1 A (= 2500 a) ac current via flexible current probe/0.1 A dc current/0.1 V ac voltage/0.1 vdc voltage/0.1 uF (= 100 uF)/1 u f (= 1000 uF) capacitance
- 3000 m operating altitude/12000 m storage altitude
- 7.5 mm flexible current probe diameter
- 1.8 m flexible current probe cable length (head to electronics connector)
- Add 0.1 x specified accuracy for each degree C above 28 deg C or below 18 deg C temperature coefficients
- 3 at 500 A (375 and 376 only)/2.5 at 600 A /1.42 at 1000 A (376 only)/add 2% for C.F. > 2 AC current via jaw/3.0 at 1100 A (375 and 376 only)/2.5 at 1400 A/1.42 at 2500 A/add 2% for C.F. > 2 AC current via flexible current probe crest factor (50/60 Hz)
- 2500 A measure ac current via iFlex™
- = 30 Ohm measure continuity
- 100 mS measure inrush
- Range - 500.0 mV dc/5.0 - 500.0 Hz frequency via jaw and flexible current probe/1000 uF capacitance, 2% +/- 5 digits (10 - 100 Hz)/2.5% +/- 5 digits (100 - 500 Hz) AC current via jaw / 3% +/-5 digits (5 - 500 Hz) AC current via flexible current probe AC current accuracy, 1.5% +/- 5 digits AC voltage/1% +/- 5 digits DC voltage accuracy
DESCRIPTION
The Fluke 376 clamp meter offers improved performance perfect for a wide range of current measurement situations. With true-rms voltage and current measurements/the Fluke 376 can read up to 1000 V and 1000 A in both ac and dc modes. Additionally/the Fluke 376 includes the new iFlex™ flexible current probe/which expands the measurement range to 2500 A ac while providing increased display flexibility/ability to measure around awkward sized conductors and improved wire access. The Fluke 376 is the direct replacement for the Fluke 337 clamp Meter.
Fluke® Clamp Meter, True RMS AC/DC, 999.9 A 1000 V AC/DC Electrical Rating, 60 kOhm Resistance, 500 Hz Frequency, 34 mm Jaw, Backlit Display, 2% +/- 5 Digits AC Current Accuracy, 1.5% +/-5 Digits Voltage Accuracy, Safety Rating: CAN/CSA-C22.2 No 61010-1-04, (2) AA, NEDA 15 A/IEC LR6 Batteries Power Source, 10 to 50 deg C Operating, 246 mm L x 83 mm W x 43 mm H Dimensions
SPECIFICATIONS
| Type | : True RMS AC/DC |
| Electrical Ratings | : 999.9 A 1000 V AC/DC |
| Resistance | : 60 kOhm |
| Frequency Rating | : 500 Hz |
| Jaw Capacity | : 34 mm |
| Display Type | : Backlit |
| AC Current Accuracy | : 2% +/- 5 Digits |
| Voltage Accuracy | : 1.5% +/-5 Digits |
| Safety Rating | : CAN/CSA-C22.2 No 61010-1-04 |
| Power Source | : (2) AA NEDA 15A IEC LR6 Batteries |
| Operating Temperature | : 10 to 50 deg C |
| Dimensions | : 246 mm L x 83 mm W x 43 mm H |
APPLICATION INFO
| Standard/Approvals | : CAN/CSA-C22.2 No. 61010-1-04|ANSI/UL 61010-1:2004|ANSI/ISA-61010-1 (82.02.01):2004|EN/IEC 61010-1:2001 to|1000V Measurement Category (CAT) III|600V Measurement Category (CAT) IV|Pollution Degree 2|EN/IEC 61010-2-032:2002|EN/IEC 61010-031:2002+A1:2008 |
| Country of Origin | : UA |